Welcome guest, is this your first visit? Create Account now to join.
  • Login:

Welcome to the NZ Hunting and Shooting Forums.

If this is your first visit, be sure to check out the FAQ by clicking the link above. You may have to register before you can post: click the register link above to proceed.

Night Vision NZ DPT


User Tag List

+ Reply to Thread
Results 1 to 7 of 7
Like Tree1Likes
  • 1 Post By Simon

Thread: Odd 300 blackout loading

  1. #1
    Member Burb122's Avatar
    Join Date
    Jul 2012
    Posts
    966

    Odd 300 blackout loading

    Always loaded my own 30 cal casts .309.

    Decided to try some 208 grain Amax .308
    These measure up consistantly at .308

    brass inner dia .298 average then flared.

    Seems like the brass is expanding quite a bit during projectile insertion.

    Ive never noticed it loading other calibers with jacketed projectiles.

    Fits in case gauge fine afterwards.

    Is this normal or am i missing something here. Name:  uploadfromtaptalk1431507264885.jpg
Views: 391
Size:  805.0 KB

    Name:  uploadfromtaptalk1431507315145.jpg
Views: 359
Size:  814.1 KB

    Name:  uploadfromtaptalk1431507374694.jpg
Views: 354
Size:  748.0 KB

  2. #2
    Member Burb122's Avatar
    Join Date
    Jul 2012
    Posts
    966
    F knows why the pics loaded sideways??

  3. #3
    Member
    Join Date
    Jun 2013
    Location
    Middle Earth
    Posts
    4,355
    Looks like your expander might not be sizing back up enough?or your dies are sizing to much down?
    Could be also due to the brass thickness.
    Are you using resized 223 cases or 221 fireball or original black out?

  4. #4
    Member
    Join Date
    Feb 2014
    Location
    Cambridge
    Posts
    685
    What's the head stamp on the case that has flared out when the projectile was seated?
    Is it the same as the others?
    I am picking that the wall thickness of that case is too thick. There are quite a few case brands that have too thick a brass around the neck to be used as 300 blackout brass.
    A Sheridan case gauge will pick this issue up once a projectile is seated. Other gauges wont.
    Don't chamber it as it will get stuck in your chamber.

    Sheridan Engineering - Ammunition Gauges
    Carpe Diem likes this.

  5. #5
    Member Burb122's Avatar
    Join Date
    Jul 2012
    Posts
    966
    its all stamped F C

    I am aware of the case brands to.

    Its really wierd. Made 4 dummy rounds and they chamber fine???

  6. #6
    Member
    Join Date
    Feb 2014
    Location
    Cambridge
    Posts
    685
    FC brass is fine. Its what I use as well.
    Good luck.

  7. #7
    Member
    Join Date
    Jun 2013
    Location
    Middle Earth
    Posts
    4,355
    Measure the diameter of the neck once projectile is seated.
    You can compare that to google info on the calibre.
    When reloading my 300 whisper I have to turn the neck down. Not so for my black out.

 

 

Similar Threads

  1. Reloading for a 300 Blackout
    By tikka in forum Reloading and Ballistics
    Replies: 4
    Last Post: 26-11-2014, 07:03 PM
  2. Projectiles for 300 Blackout
    By Bavarian_Hunter in forum Reloading and Ballistics
    Replies: 5
    Last Post: 13-08-2013, 12:40 AM
  3. First for the Blackout
    By Kiwi Greg in forum The Magazine
    Replies: 33
    Last Post: 03-06-2013, 04:35 PM

Tags for this Thread

Bookmarks

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
Welcome to NZ Hunting and Shooting Forums! We see you're new here, or arn't logged in. Create an account, and Login for full access including our FREE BUY and SELL section Register NOW!!