If this is your first visit, be sure to
check out the FAQ by clicking the
link above. You may have to register
before you can post: click the register link above to proceed.
After reading this, I would suggest full length sizing (humor me) if you don have a die then send me 3-4 cases and I will size it and you can try
I also have 6.5GAP
Thanks Mikee, it is all good. I have no issue with norma brass so will stick to it. I was just curious why the over-pressured brass could cause accuracy problem. have a great weekend!
I have a 6.5 SAUM with 0.296 NK that I can’t run Bertram brass in, necks are too thick (major pressure signs even at what should be start loads).
Didn’t bother to neck turn to see if that fixed it as ADG brass had a thinner neck and has given great accuracy.
Hi overflow50, mine is 0.2962, so same as yours. GAP later released 0.298 neck reamer, which you can use normal cases without neck turning. I neck case down from 300 saum so neck turning is a must. will check the ADG brass, thanks.
Welcome to NZ Hunting and Shooting Forums! We see you're new here, or arn't logged in. Create an account, and Login for full access including our FREE BUY and SELL section Register NOW!!
Bookmarks